Board thermal modeling

Note:

Board thermal modeling settings are used by the PowerPlay Power Analyzer. These settings do not affect timing analysis.

The following circuit board thermal modeling settings are available for supported device families:

Scripting Information

Keyword:POWER_BOARD_THERMAL_MODEL

Settings:custom | typical | "NONE (CONSERVATIVE)"

Scripting Information

Keyword:POWER_OJB_VALUE

Settings:<thermal resistance in degrees Celsius per watt>

Note:

If a specified ambient or junction temperature is above the allowable junction temperature range for the device, a warning message appears and the Quartus® Prime Standard Edition software uses the maximum allowable temperature in power analysis; if a specified ambient or junction temperature is below the allowable junction temperature range for the device, a warning message appears and the Quartus® Prime Standard Edition software uses the minimum allowable temperature in power analysis.

If the specified board temperature is outside the user-specified junction temperature range but within the allowable junction temperature range for the device, the Quartus® Prime Standard Edition software uses the specified board temperature and a warning appears in the Messages window informing you that the board temperature is outside the range you specified in Junction temperature range.

Scripting Information

Keyword:POWER_board_temperature

Settings:<temperature in degrees Celsius>

default = 25